Skip to content

Tower assembly check: do sections, cross-arms and tower foot fit together?

Enter dimensions, profiles and hole patterns of sections and cross-arms from the shop drawings. The tool compares every connection, checks the tower foot against the foundation and pit of the location and shows the tower in 3D on its foundation.

Register for free Read more in the manual

1 location free, no payment details. Runs in the browser – nothing to install. Try it without registering

Tower assembly in the tool: key figures, view of the tower to scale with cross-arms and the fit check per connection
Example from the sample project

What the tool checks

Joints of the sections

System width, profile, hole pattern, hole diameter and bolt – top of the lower section against bottom of the upper.

Cross-arm connections

Connection width of the cross-arm against the tower width at its height, plus hole pattern and hole clearance.

Tower foot in the foundation

Cast-in leg or base plate, slope, embedment, distance to the concrete edge – and unequal legs with different corner levels.

Drawings alongside

Upload shop drawings as PDF, view and measure them; each drawing can be assigned to its part.

How to proceed

  1. Foundation first. Pit, foundation and tower foot are consecutive steps at the location; the tower assembly is the fourth.
  2. Enter the parts. From the drawings: dimensions, profiles, hole patterns. A tower outline (single-level, Donau, barrel) creates the cross-arms as a template.
  3. Read the fit check. Every connection with both values and the verdict; what is not entered counts as not checked.
  4. Look at the 3D view. Pit, foundations, tower foot and tower in one view – with the terrain of the pit.

Inputs, results and calculation method

What you enter

  • Sections from bottom to top: height, system width at bottom and top, profile, hole patterns, bolts
  • Cross-arms: connection height, length, connection width, hole pattern
  • Tower foot: type, slope, embedment, corner levels for unequal legs
  • Tolerance of the dimensions
  • Drawings as PDF

What you get

  • Fit check per connection: fits, check, does not fit – with the deviation in mm
  • Tower height, lower edges of the sections, tower width at each cross-arm
  • Position of the tower foot in the foundation, distance to the concrete edge
  • View to scale and 3D view at the location; export as GLB, DXF and STL

How it is calculated

  • Joint: system width at the top of the lower section against the bottom of the upper; a deviation above the tolerance counts as “does not fit”.
  • Cross-arm: tower width at the connection height, interpolated linearly between the widths of the section, against the connection width of the cross-arm.
  • Hole patterns are compared dimension by dimension, hole diameter against bolt diameter (hole clearance).

The figures you enter are compared – there is no rule from a standard behind it. What exactly is compared is described in the manual. Go to the chapter in the manual

An example, recalculated

Two sections of 6 m each – the upper one is 20 mm narrower at the joint than the lower one. The figures are calculated by the same engine as in the application – when this page is opened.

Section 1
6.00 m high, system width 3000 mm at the bottom, 2400 mm at the top
Section 2
6.00 m high, system width 2380 mm at the bottom, 1800 mm at the top
Tolerance
1 mm
QuantityResultCalculation
Tower height12.00 msum of the sections
Joint section 1 – section 2: system width2400 mm / 2380 mmtop of the lower section against bottom of the upper section
Verdictdoes not fitThe upper section is 20 mm narrower at the bottom than the lower one at the top.
Profile and hole patternnot checkednot entered on both sides – the checklist says so instead of guessing

The check compares the figures you enter from the drawings. It does not read a drawing.

Limits

What the tool does not do – so that it is clear what the result is good for. Results are planning aids, not construction documents.

  • The check does not read a drawing: only the figures entered are compared.
  • No verification of load-bearing capacity – neither for the tower nor for joints, bolts or the foundation.
  • It replaces neither workshop inspection nor trial assembly.
  • The 3D view shows the entered dimensions in simplified form; it is not a design drawing.

Frequently asked questions

What is the check good for if it does not read a drawing?

It makes you write the connection dimensions of both sides of a joint next to each other – and finds the deviation before the parts hang from the crane. What is entered on one side only is reported as not checked.

What are unequal legs?

A tower foot whose legs stand at different levels, for example on a slope. The tool takes the level of every corner and checks the position of every leg in its foundation; it can suggest the ground levels of the corners from the terrain model.

In which formats is the 3D view available?

With a subscription as GLB, DXF and STL. The STL file is a closed solid.

Try it on your next construction project.

One location free, all tools. No credit card, no subscription.

Register for free