9 Tower assembly check

Sections and cross-arms of a lattice tower: do dimensions, profiles and hole patterns at the joints match? With the shop drawings as PDF alongside and the tower in 3D on its foundation.

Creating, drawings, saving

  • Create: on the location page, the card Tower assembly check › Create tower assembly and check. There is one tower assembly per location; the card then shows sections, cross-arms, height and how many comparisons do not fit or need checking.
  • Drawings: in the section Drawings, upload the shop drawings with Upload PDF – up to 12 files per location, at most 25 MB each. A click on the name shows the drawing in the drawing view next to the list, ↗ in a window of its own.
  • Drawing view: turn pages with ‹ ›, zoom with + and −, Width fits the sheet; dragging with the mouse or swiping with a finger moves the section shown. Four tools sit above it:
    • Tap a value: select a field in the form first, then tap a label in the drawing – dimension figure, profile, ∅ 22 or M20 are in the field. Works only if the lettering is stored as text in the file.
    • Scale: tap two points of a known dimension and enter its length in mm. If a scale such as 1:10 is written on the sheet as text, the page offers it – it is only right if the sheet is stored at original size. To check, measure a second known dimension.
    • Measure distance: tap two points; circles snap to their centre. The length can be put into the selected field.
    • Pick up hole pattern: tap the holes of a connection. The page writes the hole pattern as x/y; x/y from the smallest x and y and states the diameter if all tapped circles are the same size – both can be put into the selected field. A second tap removes a hole again.
  • Items found: if the lettering of the drawing is stored as text in the file, the page lists whatever looks like a profile (L 200x20), hole (∅ 22), bolt (M20), scale or dimension figure – with its frequency. Select a field in the form first, then tap an item: the value is in the field.
  • Parts as cards: tower foot, every section and every cross-arm are a collapsible card. Collapsed, it shows the essentials (height, widths, profile) and a coloured dot with its verdict; cards with deviations are expanded when the page opens. Add section and Add cross-arm append a part, remove takes it out – the following ones move up. Bottom joint as section below sets width, hole pattern, hole Ø and bolt to the values of the lower section: use only if the drawing shows the same – the check then compares two identical figures.
  • Enter and check: at the left, the connection dimensions per section and per cross-arm; at the right, the check. Every change is checked immediately. Save or CtrlS stores the state at the location.
  • Delete: a drawing via the bin next to its name; the whole tower assembly on the location page in the menu ⋯ of the card – its drawings are deleted with it.
  • Whoever has read-only access in the project sees check and drawings but uploads nothing and does not save.

Inputs

Sections
up to twelve, from bottom to top. For a rectangular tower additionally width across at bottom and top (empty = square); the connection width of a cross-arm is checked against the first width. Per section: designation, height in m, width at bottom and width at top (system width of the tower at the joint) in mm, leg profile – and for the joint at bottom and the joint at top hole pattern, hole diameter and bolt each.
Cross-arms
up to twelve, reaching to both sides or only to the left or right (for the 3D picture). Per cross-arm: designation, connection height above the tower base in m, overall length, connection width in mm, profile – plus hole pattern, hole diameter and bolt of the cross-arm and the counterpart on the tower (hole pattern and hole diameter from the drawing of the section).
Tower configuration as a preset
Single level (one cross-arm), Danube (two, the longer one below) and Barrel (three, the middle one longest) create the cross-arms: heights as a share of the tower height, connection width equal to the tower width at that height. Lengths and heights are placeholders – enter the dimensions from the tower list. Existing cross-arms are replaced only after confirmation.
Taper and kink joint
Every section has its own taper: (width at bottom − width at top) ÷ height, in cm per metre. The field shows it as soon as height and widths are entered – or you enter the taper and the page calculates the width at top (only the widths are stored). Most towers have a kink joint: the lower part is spread more than the shaft, and at one joint the taper decreases. Simply enter the sections with their widths – the page detects the kink itself and names it below the field. If the tower kinks within a section, split it into two sections there.
Type of splice
per section for its bottom splice. Lap splice (default): the hole patterns of both parts must coincide – every bolt passes through both. Butt splice with cover plates: the parts butt, each side has its own hole group at the cover plate; the position of the two patterns is then not checked against each other, the check states the number of bolts per splice (sum of both groups) and refers to the drawing of the cover plate. Hole diameter, bolt and hole clearance are still compared.
Hole pattern
as text, in one of three notations: 2x3 80x60 – grid of 2 columns and 3 rows at 80 mm and 60 mm spacing; 4x 70 – row of 4 holes at 70 mm spacing; 0/0; 60/0; 0/80 – single holes with x/y in mm. The reference point is free: the positions of the holes relative to each other are compared.
Drawing for a part
In the card of a section or a cross-arm one of the uploaded drawings can be assigned; open shows it in the drawing view. In the mode Hole pattern the view suggests, after the first hole tapped, the remaining holes of the group (Complete the group: circles of the same diameter connected via neighbours at a distance of at most eight diameters) – a suggestion: a tap removes whatever does not belong.
Profile
as in the drawing: L 200x20, L 200x100x12, HEB 200. Notation and spaces do not matter.
Bolt
M20, also with length or strength class (M20x70, M20-8.8) – the nominal diameter counts.
Permissible deviation
in mm, default 1. Up to this value two dimensions and the positions of two holes count as identical.

Tower foot, inclined foot and foundation

The tower foot is a tool of its own in the category Civil works: its card and step 3 of the foundation works open a view that shows only the foot, the lowest section and the foundation. It lives in the same saved state as the tower parts – both can be edited on their own, one tower is saved. The section describes how the lowest section goes into the foundation. Two types:

Leg cast in concrete
The stub angle is set on the blinding layer, aligned and cast in. Inclined: it follows the slope of the lowest section (the usual case) or has its own slope from the drawing; vertical: it stands plumb. Plus: height of the joint above top of foundation, length in concrete (empty = down to the blinding layer), profile, hole pattern, hole Ø and bolt of the joint to the lowest section.
Base plate on anchor bolts
Hole pattern and hole Ø of the base plate, anchor bolts and the pattern of the anchors according to the foundation drawing.
For both
Leg spread (spacing of the legs at top of foundation; empty = calculated from section 1), foundation spacing centre to centre (empty = foundation centre under the foot), the required distance foot axis – concrete edge from foundation drawing or structural design (empty = the distance is only reported) and – for unequal legs – per corner A–D the level of the top of foundation above sea level and the leg extension.

What is checked: leg spread, slope, profile, hole pattern, hole Ø, bolt and clearance against the lowest section – and against the foundation saved by the foundation at this location: embedment (does the foot stand on the blinding layer, end above it, or is it longer than the foundation is high?), foot point and the smallest distance of the foot axis to the concrete edge in every step. With four foundations one stands at each leg, with one (block, slab) all four feet stand in it.

The excavation is the basis: if the location has an excavation with four pits, the foundations stand where the excavation simulation places them – their centres at the distance from the tower centre, their edges radial, i.e. diagonal to the tower faces. The distance to the concrete edge is calculated in this position (in the example below: 500 − 80 · √2 = 387 mm instead of 420 mm). The foundation spacing then comes from the excavation; a differing spacing entered is reported by the check, the calculation uses the excavation. Without an excavation the spacing entered applies, with edges parallel to the tower faces.

Unequal legs: if the four legs stand at different levels above sea level (sloping ground), legs of different length make up the difference. Per corner, the level of the top of foundation and the leg extension from the tower drawing are entered. The page calculates, per corner, the level of the joint to the lowest section and reports every corner that falls out of the plane of the others (to the permissible deviation of the dimensions). In the picture every corner with its foundation stands lower by as much as its level lies below the highest.

Level of the joint of a corner = top of foundation [m a.s.l.] + joint above the foundation + leg extension

Suggest corner levels from the terrain model enters for every corner: ground level at the centre of its foundation (official elevation model, position from the excavation with four pits) plus the height of the top of foundation above ground from the foundation tool. This is a suggestion from the terrain – the survey and the foundation drawing are decisive. Available throughout Germany, as in the excavation simulation.

Example: tops of foundation at 123.000 / 121.500 / 122.500 / 123.000 m a.s.l., joint 0.30 m above the foundation. With leg extensions of 0 / 1.50 / 0.50 / 0 m all four joints lie at 123.300 m a.s.l. Without the extension at corner B its joint would lie 1.500 m below the plane of the others – “does not fit”.

Slope per face n = (width at bottom − width at top) ÷ 2 ÷ height of the section [mm/m] · across the corner: n · √2

Leg spread at top of foundation = width at bottom of section 1 + 2 · n · height of the joint above the foundation

Offset of the foot point per face = n · length in concrete

Example: section 1 with 3000/2400 mm over 6 m has n = 50 mm/m. Joint 0.30 m above the foundation: leg spread 3030 mm. In a 2.40 m high foundation the foot point is 120 mm further out per face (170 mm across the corner); at the base of a shaft 1.00 m wide and 1.60 m high it is 80 mm – 500 − 80 = 420 mm remain to the concrete edge.

3D picture and files: this page, the foundation tool and the location page show the same foundation in 3D: excavation, blinding layer, foundations (translucent), the feet in them and the tower above. On the location page the picture can be saved as a 3D file (GLB) Subscription for viewers (Windows 3D Viewer, Blender) and as DXF for CAD Subscription – faces per layer (ground, excavation, blinding layer, foundation, tower foot, tower), unit metres. STL (solids) Subscription outputs the same as closed solids: the body of earth with the excavation pit (ground with excavation, vertical side walls, flat base) and foundation and tower merged into one solid (no faces inside where the leg sits in the concrete) – for CAD, volumes and 3D printing. The table Position of the legs gives, per corner, the dimensions from the tower centre at top of foundation and at the foot point.

Interplay: the foundation tool and this page tell each other whether the foot stands in the saved foundation. Transfer to the excavation simulation (foundation) sets, for four foundations, the distance from the tower centre from the foundation spacing (spacing ÷ 2 · √2); if the excavation later deviates from it, the comparison here says so.

Result

  • Four tiles: height of the tower with number of parts, how many comparisons fit, need checking and do not fit.
  • Elevation: the tower to scale from the side. Each joint carries a marker, each cross-arm a colour: fits, check, does not fit – grey where nothing is entered.
  • Checklist: one item per connection with what stands out.
  • Structure: sections and taper: per section the bottom edge, height, widths, taper in cm/m and the slope of the leg member per face (half the taper, also as 1 : x); the last column says whether the joint at the top is continuous or a kink joint, with the kink angle per face. The view writes the taper next to every section and “Kink” at the joint.
  • 3D view: sections, joints and cross-arms as a rotatable picture. If a foundation is saved at the location, the tower stands on its top: with one foundation in its centre including the excavation, with four identical foundations at the four legs. Foundation
  • Comparison at the connections: the table with every compared quantity – at the left the lower section or the tower, at the right the upper section or the cross-arm, plus verdict and finding. Copy values (for Excel) Subscription and Download as PDF Subscription output them.

Purpose, assumptions and limits

Purpose
To find, before delivery and erection, where the shop drawings of two parts do not state the same connection dimensions – before it shows on the tower.
Typical use
Checking the drawings of consecutive sections against each other; cross-arms against the section they sit on; comparing revised drawing versions; discussing the erection sequence with the 3D picture.
For whom
Overhead line construction, erection, site management, work preparation.
What is compared
  • Joint of two sections: width at top of the lower against width at bottom of the upper; leg profile; hole pattern (number and positions of holes); hole diameter; bolt; hole clearance.
  • Taper at the joint: below and above every joint. Equal (within the permitted deviation, calculated over the height of the upper section): continuous leg member. Smaller towards the top: kink joint – the verdict is “fits”. Larger towards the top: “check”, because the stronger taper is normally at the bottom. If a lap splice is entered at the kink, the verdict is “check”: the leg members meet there in different directions, and a butt splice with kinked cover plates is usual.
  • Cross-arm on the tower: connection width against the tower width at the connection height; hole pattern and hole diameter of the cross-arm against the counterpart on the tower; hole clearance.
Technical limits
  • The check compares entered figures. It does not recognise by itself which dimension a figure in the drawing belongs to – items found and the drawing view are a reading aid, entering is done by hand.
  • Tower foot: what is checked is the axis of the foot (system line) – not the edge of the profile, not cleats or reinforcement. Which distance to the concrete edge is necessary is laid down by the foundation drawing and the structural design; the page knows no standard value for it and only judges against the dimension entered. The edges of the foundations are parallel to the tower faces, all corners have the same foundation. With unequal legs every corner stands lower by the difference of its level to the highest corner and – at the slope of the foot – further out. If the excavation knows a sloping ground, the page compares its fall between the corners with the levels entered; the levels themselves come from the survey or the foundation drawing, not from the page. The foundation tool does not model pile foundations or foundations of other shapes.
  • 3D picture and 3D files are an illustration: legs, base plates, cross-arms and joint marks are symbols without true thickness; if the pits of the four foundations overlap, their enclosing rectangle is drawn as one common pit. The terrain model of the excavation simulation is not included.
  • Measuring in the drawing is as accurate as the drawing, the scale and the tap: circles stored as lines snap to their centre; free points lie where you tapped. Distorted sheets or sheets not to scale (scan, detail, “not to scale”) give wrong lengths. The dimension written in the drawing is decisive, not the measured value.
  • Scanned drawings and drawings whose lettering is stored as lines have no readable text: items found and Tap a value stay empty. In scanned drawings circles are only pixels too – nothing snaps there, points are tapped freely. The page recognises circles drawn as arcs or polygons; not ellipses, slotted holes or holes in oblique view.
  • Different leg profiles at a joint are common for towers (spliced joint with packing) – the verdict is therefore “check”, not “does not fit”.
  • Hole clearance: the difference between hole diameter and bolt is stated. Which clearance is permissible is laid down by the execution standard and the drawing; the page only judges if the bolt does not pass through the hole or the clearance exceeds 3 mm.
  • Kink joint: the check detects it from the widths and calculates the angle; it knows neither the cover plates nor the bracing. The note on the bent cover plates at the kink is a reminder, not a verification. A tower without a kink and a tower with several kinks are notes, not errors. The tower width at the height of a cross-arm always follows the section it sits on.
  • No load-bearing capacity, no manufacturing and erection tolerances, no parts lists, no bolt lengths and grip lengths, no diagonals and bracing members.
  • The tower in the 3D picture is an envelope: sections as frusta with a square plan, cross-arms as beams.
Data protection
What is stored: the inputs, the uploaded drawings, a list of the items found per drawing and who saved or uploaded when – at the location, visible to everyone allowed to open the project. The drawings go to no third party: the server reads only their text, the drawing view renders them in your own browser (pdf.js, loaded from the baustellen.tools server). More in the privacy policy.

Method and example

Tower width at the height of a cross-arm: linear between the bottom and top width of the section.

b(h) = bbottom + (btop − bbottom) · (h − bottom edge of the section) ÷ height of the section

Hole pattern: both patterns are shifted to their smallest x and smallest y and sorted; the distance is compared hole by hole. If the largest distance is within the permissible deviation, the pattern fits. If it only fits after mirroring, the verdict is “check” – the two drawings then show the connection from different sides.

Example (the defaults of the page): Section 1 – 6 m, 3000/2400 mm, L 200x20; Section 2 – 6 m, 2400/1800 mm, L 180x18; Cross-arm 1 at 10 m height, connection width 2000 mm
ConnectionQuantityComparisonVerdict
Section 1 – Section 2System width2400 mm versus 2400 mmfits
ProfileL 200x20 versus L 180x18check – common at the joint
Hole pattern2x4 80x70 versus 2x4 80x70: 8 holes, positions identicalfits
Hole diameter, bolt∅ 22 and M20 on both sides; hole clearance 2 mmfits
Cross-arm 1 on Section 2Connection width2400 + (1800 − 2400) · (10 − 6) ÷ 6 = 2000 mm versus 2000 mmfits
Hole pattern, hole diameter2x2 60x60, ∅ 18 on both sides; M16: hole clearance 2 mmfits

Typical input errors:

  • Width in metres: widths, hole patterns and diameters are in mm (3000, not 3.0).
  • Grid without spacings: 2x3 alone is not enough – 2x3 80x60.
  • Top and bottom swapped: “joint at top” of the lower section belongs to “joint at bottom” of the upper one.
  • Axis dimension and outer dimension mixed: take the same dimension in both drawings – system width over the centroidal axes or outer edge of the leg.

Something missing or unclear? Write to info@baustellen.tools.