Minimum width to EN 1610
From nominal size and trench depth – the larger value applies. Your own bottom width, such as that of the trench box, is checked against it.
Length, depth and nominal size are enough: the tool gives the minimum width to EN 1610, the excavation, the pipe zone material, the backfill and the soil left over – with a cross-section, a checklist and every calculation shown.
Register for free Read more in the manual
1 location free, no payment details. Runs in the browser – nothing to install. Try it without registering
From nominal size and trench depth – the larger value applies. Your own bottom width, such as that of the trench box, is checked against it.
Vertical walls with shoring or a slope with an angle; the soil class to DIN 4124 determines how steep a slope may be without verification.
Bedding, sidefill and cover in m³ and t, main backfill, topsoil or road structure separately.
What subsoil is left over – in situ and loose with your bulking factor, with or without reuse.
The table values have been checked against documents that reproduce EN 1610 and DIN 4124 – not against the text of the standards. All formulas and tables are in the manual. Go to the chapter in the manual
50 m trench, 2.00 m deep, DN 300, vertical with shoring. The figures are calculated by the same engine as in the application – when this page is opened.
| Quantity | Result | Calculation |
|---|---|---|
| Bottom width | 0.90 m | the larger of OD + 0.50 m = 0.80 m and the minimum width for the depth = 0.90 m |
| Excavation, in situ | 90.0 m³ | 0.90 · 2.00 · 50.0 |
| Excavation, loose | 112.5 m³ | 90.0 · 1.25 |
| Pipe zone material | 28.0 m³ · 50.3 t | bedding, sidefill and cover, without the pipe |
| Main backfill | 58.5 m³ | from the pipe zone to the surface |
| Surplus soil, in situ | 31.5 m³ | excavation − main backfill |
| Shoring area | 200 m² | 2 · depth · length |
These are the example values the tool starts with.
No login, nothing saved: enter values, and the result is calculated by the same engine as in the application.
Calculated with bedding 0.10 m, cover 0.30 m and bulking factor 1.25. In a project: pipe zone, surface layer, reuse, cross-section, checklist and quantity table as PDF.
What the tool does not do – so that it is clear what the result is good for. Results are planning aids, not construction documents.
EN 1610 gives two minimum widths: one from the outer diameter of the pipe plus an allowance per nominal size, one from the trench depth. The larger value applies. For DN 300 in a 2 m deep shored trench this is 0.90 m.
Yes. You choose the slope angle; the checklist compares it with the angle DIN 4124 permits for the chosen soil without verification.
With a subscription you copy the quantity table for Excel and output a sheet with inputs, cross-section, checklist and quantities as PDF.
All tools work at the same location with the same coordinate – what is created in one is available in the next.
One location free, all tools. No credit card, no subscription.
Register for free