Skip to content

5 Escape and rescue plan

The notice to DIN ISO 23601 and ASR A1.3/A2.3: draw the floor plan, place escape routes and safety signs – for each viewing position a correctly oriented sheet is produced.

Layout

Create rescue plan in the location list or on the location page – or in the tool switcher of another tool – creates the plan: the object from project and location, the plan author from company and name of your account, the company logo from the plan you last edited.

Editor of the escape and rescue plan with a container complex and escape route
At the left the building parts, at the top the floors, at the right the tabs Object, Insert, Title block, Floors, Check and Sheet.

Larger and Smaller zoom around the centre of the drawing area. In the tab Title block, Enter the coordinate of the location enters the coordinate as the address – the place reference for the emergency call where there is no postal address.

  • At the left the tools in the groups Building parts, Rescue, More and View – in two columns on a large screen; above the plan the floors (ground floor, 1st floor …, “+” adds one).
  • At the right the tabs Object (the selection), Insert (containers, safety signs), Title block, Floors, Check and Sheet.
  • The header is the same as in the other tools – project, location, tool switcher, save status – with ↶ ↷, Save, Sheet (view as printed) and PDF Subscription at the right. The plan is also saved automatically, four seconds after the last change.
  • At the bottom the hint for the selected tool, coordinates, sheet scale, the grid for snapping (1 cm to 1 m) and at the right the ? with all mouse, touch and keyboard commands (also the key ?).
  • If nothing has been drawn on the floor yet, the tab Object shows the first steps as buttons: Place container, Drag a room, Draw a wall, Trace a floor plan and – if the location has a construction sequence plan – “From the construction sequence plan”.

Walls and rooms

  • Wall W: click the corners. Type the length of the next wall and Enter; Tab switches between length and angle. Snapping is to corners, edges, 15° steps and the grid; Shift draws freely. Double-click or Enter finishes.
  • Room R: drag a rectangle of walls.
  • Every length and every angle appears as a tag in the drawing – click it and type the new value. For rectangles the opposite edge moves along and the room stays rectangular.
  • Corners can be dragged, inserted and deleted; the tab Object lists all edges as a table.

Containers

Container C or tab Insert › Container: the sizes as tiles with plan, dimensions and key value – single containers at the left, double containers at the right: 10 ft, 20 ft, 20 ft premium, storage 10 and 20 ft, plus “Custom dimensions” and the entrance stairs.

  • Click a tile, then click in the plan; every further click places the next one, Esc finishes. Near another container it attaches flush.
  • Q/E rotate by 90° (with Shift 15°), M mirrors the end walls (door and window to the other side), ShiftM swaps front and back.
  • In the tab Object: Label in the plan (office, sanitary, WC, changing room, first aid, storage … by click or typed in), Change size …, rotate, mirror, add another “beside” or “behind”, “Doors and windows as in the size template”. Every opening can be moved, flipped or deleted.
Tab Insert with the container sizes as tiles

Doors, windows, stairs, lift

  • Place a door T in a wall or a container; it opens towards the side the mouse is on. “Emergency exit” places the sign E002 next to it.
  • Window F likewise.
  • Stairs S: drag the walking line from bottom to top.
  • Place a lift A; Q/E rotate it beforehand.

Escape routes, areas, safety signs

  • Draw an escape route L from the room to the exit – the arrows point to the last point. In the tab Object: width, “Second escape route” (light with outlined arrows), Reverse direction, the segments with length and direction.
  • Area U: highlight a corridor or stairwell in green (RAL 6019, stairwells RAL 6024).
  • Signs Z or tab Insert › safety signs: escape and fire-protection signs to ISO 7010 (E001–E030, F001–F009, P020) in standard colours. On rotated sheets, emergency exit signs run in the same direction as in the plan.
  • Text X for room names and notes, Surroundings G for fence, path, plot boundary and neighbouring buildings.

Viewing position “You are here”

Viewing position P: click where the plan will hang and drag towards the wall you face when reading it. For each position a separate sheet is produced, correctly oriented: what lies in front of the viewer is at the top of the sheet. For large buildings, “Drag view area” limits the sheet to one part; the overview plan marks it.

Measuring

Measure D in the group View measures distances and chains: click the points – as in drawing they snap to corners, edges, 15° directions and the snap grid (Shift: without snapping). Each segment carries its length; from two segments on, the total is at the end, and the footer states the result. Double-click or Enter finishes, the next click measures anew, Backspace removes the last point, Esc clears the measurement, a second Esc ends the tool. Measurements are for viewing only.

Floors, template and construction sequence plan

  • Tab Floors: + Floor, + Copy of the floor (everything except viewing positions, assembly point and surroundings), name and short form, order with ↑ ↓, delete with ×. The floor below appears faintly for alignment.
  • Tracing template: load a floor plan as PNG or JPEG (scan, screenshot), use Set scale to click two points of a known distance and enter the length, then move, rotate and set the opacity. The template is not printed.
  • Aerial image as a template: if the location has a coordinate, Load aerial image fetches the orthophoto of the German federal state around the location – extent 50 to 400 m – to scale and north-up; the location lies at the origin. Like any template it is not printed; the source note is shown below.
  • Transfer from the construction sequence plan: if the location has a construction sequence plan, containers (size and label recognised), site fence, site road and access route come into the floor in the same position.
  • With CtrlC and CtrlShiftV elements travel in the same place to another floor – or into the plan of another location.
Tab Floors with three floors, template and transfer from the construction sequence plan

Title block, sheet and PDF

Tab Title block:

  • Object, address, plan author, plan number (start), index, date and company logo (PNG or JPEG; a white margin is cropped, new plans take it over).
  • Sheet: format DIN A4 (single rooms only) to A0, orientation, scale (“automatic” takes the largest from 1 : 50 to 1 : 5000 that fits), sign size, north, tick boxes for north arrow, overview plan with assembly point and reference to the standard.
  • Assembly point as a description, What to do in case of fire and in case of accidents (with a default text that can be changed freely; “Restore standard texts”) and further telephone numbers.
Tab Title block with object, address, plan author, plan number and company logo

Tab Sheet shows every sheet exactly as it goes into the PDF: choose the sheet at the top, View large opens it full-screen.

The PDF Subscription in the header contains all sheets, PDF of this sheet only the selected one. If the project is not in a subscription, the sheet carries the diagonal note “Preview – PDF with subscription”.

The sheet is produced in the language in which you request it: title, legend, title block labels and the unchanged default rules of conduct. Language

Tab Sheet with sheet selection, View large, PDF of this sheet and the preview
Finished sheet Escape and rescue plan ground floor with legend, rules of conduct and title block
A finished sheet: header in safety green, floor plan with escape routes, at the right overview, legend and rules of conduct, at the bottom the title block.

The program lays out the sheet itself: it measures how much space overview, legend, rules of conduct, telephone numbers and title block need and chooses the arrangement with the best scale. If something does not fit, the plan becomes one step smaller; long entries in the title block are wrapped.

Checklist

Tab Check (the number on the tab counts the open items):

  • Errors: a viewing position, the assembly point, an escape route per floor or an entry in the title block is missing.
  • Warnings: no first-aid or fire-protection signs, an emergency exit without marking, A4 for more than one room, scale smaller than 1 : 250, signs that cover each other, texts that do not fit completely on the sheet.
  • Below that all sheets with number, floor, format and scale.
Tab Check: all mandatory details are present, list of sheets

Purpose, assumptions and limits

Purpose
Draw the escape and rescue plan as a notice: floor plan, escape routes, safety signs, position of the viewer, rules of conduct and title block on a sheet that lays itself out.
Typical use
Container complexes of the site facilities, site offices and accommodation; buildings under conversion; a new notice whenever containers are moved, routes are relocated or assembly points change.
For whom
Site management, health and safety coordination, occupational safety specialists – and the competent person who checks the plan before it is displayed.
Units
Metres in the floor plan, millimetres on the sheet; scale 1 : n; angles in degrees; sheet formats DIN A4 to A0.
Calculation method
  • Scale: length on the sheet in mm = real length in m × 1000 ÷ n. “Automatic” first measures how much space header, overview, legend, rules of conduct and title block need, and then takes from the series 1 : 50, 100, 150, 200, 250, 300, 400, 500, 750, 1000, 1500, 2000, 2500, 5000 the largest scale at which the floor plan fits into the remaining field.
  • Correctly oriented: every sheet is rotated by the viewing direction of its position – what lies in front of the viewer is at the top.
  • Minimum sizes on the sheet, regardless of the scale: outer walls at least 1.6 mm, partition walls 0.6 mm, lettering 2 mm cap height, safety signs 7 mm (default 9 mm). On sheets larger than A3 the lettering grows with the format.
Example
A container complex of 18.2 × 7.3 m with one viewing position: on A3 landscape “automatic” chooses 1 : 100 – the floor plan then measures 182 × 73 mm; on A2 landscape 1 : 50 with 364 × 146 mm. A building of 40 × 20 m comes out at 1 : 150 on A3 landscape and at 1 : 100 on A2. More legend entries or longer texts can make the scale one step smaller.
Assumptions
The floor plan matches the actual building – the program does not check whether a wall, door or staircase is really there. Each floor is one level; stairs connect them only as symbols. Containers have the dimensions of the size chosen.
Technical limits
  • No fire safety concept and no design: the program does not check escape route lengths, widths, number of exits or numbers of people.
  • The checklist finds missing mandatory details and presentation errors, not technical deficiencies of the escape route.
  • Not a fire brigade plan to DIN 14095 and not a fire protection plan.
  • Whether a notice is required at all and where it hangs is decided by the employer’s risk assessment.
Regulations
DIN ISO 23601 (escape and evacuation plan signs), ASR A1.3 (safety and health signage), ASR A2.3 (escape routes and emergency exits), DIN EN ISO 7010 (safety signs). The ASR are German workplace rules; what counts is the current edition in each case. Outside Germany, the local rules apply.
Typical input errors
  • Viewing position without direction to the wall: the sheet is then rotated the wrong way. Drag from the position towards the wall you face when reading.
  • Escape route in the wrong direction: the arrows point to the last point – which must be at the exit. “Reverse direction” turns it round.
  • Template without scale: a traced scan is only correct once a known distance has been entered with “Set scale”.
  • Sheet too small: A4 is intended for single rooms only; if the scale becomes smaller than 1 : 250, choose the next larger format or drag a view area.
  • Assembly point only described: the checklist requires the sign E007 in the plan. If the assembly point lies outside the sheet, switch on the overview plan.
  • Default texts adopted unchecked: adapt rules of conduct and telephone numbers to the site – emergency number, first aiders, extension of the site management.
Data protection
The plan contains what you enter: object, address, plan author, telephone numbers and the company logo. Names and extensions of individuals then appear on every notice and in every PDF – only enter what may be shown there. An aerial image used as a template is fetched by the server from the map service; the service learns the map extent, not your network address. More in the privacy policy (German).

Keyboard shortcuts in the rescue plan

Key or mouseEffect
V W R CSelect, Wall, Room, Container
T F S ADoor, Window, Stairs, Lift
L U Z PEscape route, Area, Safety sign, Viewing position
X G DText, Surroundings, Measure
Enter · double-clickfinish wall, escape route or area; apply typed length
Tabwhile drawing, switch between length and angle
Backspacewhile drawing, take back the last point
Shiftwhile drawing, without snapping; with a click, add to or remove from the selection
Esccancel, end the tool, clear the selection
Q / Erotate by 90°, with Shift by 15°
M · ShiftMmirror container: end walls · front and back
← ↑ → ↓move the selection by the snap grid, with Shift by 1 m
Tab Object › Movemove the selection without dragging: type the step in metres, click an arrow button; the arrow buttons on the left under “View” move the view
Deldelete
CtrlDduplicate
CtrlC CtrlX CtrlVcopy, cut, paste at the mouse
CtrlShiftVpaste in the same place – also into another floor
CtrlAselect everything on the floor
CtrlZ / CtrlYundo, redo
CtrlSsave
# · Homegrid on/off · fit everything
?overview of all mouse, touch and keyboard commands
+ / - · mouse wheelzoom
Drag on empty space · Space + dragpan the view; with Shift drag a selection frame

Something missing or unclear? Write to info@baustellen.tools.